ALDRICH CHEMICAL CO INC -- ACETIC ACID, 99.7%, A.C.S. REAGENT, 24285-3 -- 6810-00N057757
===================== Product Identification =====================
Product ID:ACETIC ACID, 99.7%, A.C.S. REAGENT, 24285-3
MSDS Date:05/10/1988
FSC:6810
NIIN:00N057757
=== Responsible Party ===
Company Name:ALDRICH CHEMICAL CO INC
Address:1001 W ST PAUL AVE
Box:355
City:MILWAUKEE
State:WI
ZIP:53201
Country:US
Info Phone Num:414-273-3850
Emergency Phone Num:800-231-8327
CAGE:60928
=== Contractor Identification ===
Company Name:ALDRICH CHEMICAL CO INC
Address:1001 WEST ST PAUL AVE
Box:355
City:MILWAUKEE
State:WI
ZIP:53233
Country:US
Phone:414-273-3850
CAGE:60928
============= Composition/Information on Ingredients =============
Ingred Name:ACETIC ACID (CERCLA)
CAS:64-19-7
RTECS #:AF1225000
Fraction by Wt: >99.7%
OSHA PEL:10 PPM
ACGIH TLV:10 PPM;15 STEL
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
===================== Hazards Identification =====================
LD50 LC50 Mixture:LD50:(ORAL,RAT) 3530 MG/KG.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:HARMFUL IF SWALLOWED, INHALED OR
ABSORBED THROUGH SKIN. MATERIAL IS EXTREMELY DESTRUCTIVE TO TISSUE
OF MUCOUS MEMBRANES & UPPER RESPIRATORY TRACT, EYES & SKIN.
INHALATION MAY BE FATAL AS A RESUL T OF SPASM, INFLAMMATION & EDEMA
OF THELARYNX & BRONCHI, CHEMICAL PNEUMONITIS & PULMONARY EDEMA.
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:SYMPTOMS OF EXPOSURE MAY INCLUDE
BURNING SENSATION, COUGHING, WHEEZING, LARYNGITIS, SHORTNESS OF
BREATH, HEADACHE, NAUSEA & VOMITING.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INGEST:CALL MD IMMED . EYES:IMMED FLUSH W/COPIOUS AMTS OF
WATER FOR AT LST 15 MINS. ASSURE ADEQ FLUSHING BY SEPARATING
EYELIDS W/FINGERS. SKIN:IMMED FLUSH W/COPIOUS AMTS OF WATER FOR AT
LST 15 M INS WHILE REMOVING CONTAM CLTHG & SHOES. WASH CONTAM CLTHG
BEFORE REUSE. DISCARD CONTAM SHOES. INHAL:REMOVE TO FRESH AIR. IF
NOT BRTHG GIVE ARTF RESP. IF BRTHG IS DFCLT, GIVE OXYGEN. CALL MD.
===================== Fire Fighting Measures =====================
Flash Point:104F,40C
Lower Limits:4%
Upper Limits:16%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL POWDER, ALCOHOL OR
POLYMER FOAM.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . COMBUSTIBLE.
================== Accidental Release Measures ==================
Spill Release Procedures:WEAR NIOSH/MSHA APPRVD SCBA, RUBBER BOOTS &
HEAVY RUBBER GLOVES. ABSORB ON SAND OR VERMICULITE & PLACE IN
CLOSED CONTAINERS FOR DISPOSAL. VENTILATE AREA & WASH SPILL SITE
AFTER MATERIAL PICKUP IS COMP LETE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:DO NOT GET IN EYES, ON SKIN, ON
CLOTHING. DO NOT BREATHE VAPOR. READILY ABSORBED THROUGH SKIN.
CORROSIVE.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:WEAR APPROPRIATE NIOSH/MSHA APPROVED RESPIRATOR.
Ventilation:USE ONLY IN A CHEMICAL FUME HOOD.
Protective Gloves:CHEMICAL-RESISTANT GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS(SUPDAT)
Other Protective Equipment:WEAR OTHER PROTECTIVE CLOTHING. SAFETY
SHOWER & EYE BATH.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
EYE PROT:& FULL LENGTH FACESHIELD .
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:>243F,>117C
Melt/Freeze Pt:M.P/F.P Text:>61F,>16C
Vapor Pres:11.4 @ 20C
Vapor Density:2.07
Spec Gravity:1.049
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
BASES.
Stability Condition to Avoid:PROTECT FROM MOISTURE.
Hazardous Decomposition Products:TOXIC FUMES OF: CARBON MONOXIDE,
CARBON DIOXIDE.
==================== Disposal Considerations ====================
Waste Disposal Methods:THIS COMBUSTIBLE MATERIAL MAY BE BURNED IN A
CHEMICAL INCINERATOR EQUIPPED W/AFTERBURNER & SCRUBBER. OBSERVE ALL
FEDERAL, STATE & LOCAL LAWS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.