PRESSURE-LUBE INC -- CLARK CHAIN AND CABLE LUBE AEROSOL -- 9150-00N026476
===================== Product Identification =====================
Product ID:CLARK CHAIN AND CABLE LUBE AEROSOL
MSDS Date:01/02/1991
FSC:9150
NIIN:00N026476
=== Responsible Party ===
Company Name:PRESSURE-LUBE INC
Box:56
City:BUTLER
State:WI
ZIP:53007
Country:US
Info Phone Num:414-781-7660
Emergency Phone Num:414-781-7660
CAGE:IO203
=== Contractor Identification ===
Company Name:PRESSURE LUBE INC
Address:N57 W13400 CARMEN AVE
Box:56
City:MENOMONEE FALLS
State:WI
ZIP:53051
Country:US
Phone:414-781-7660
CAGE:1W282
Company Name:PRESSURE-LUBE INC
Box:56
City:BUTLER
State:WI
ZIP:53007
Country:US
Phone:414-781-7660
CAGE:IO203
============= Composition/Information on Ingredients =============
Ingred Name:PROPANE
CAS:74-98-6
RTECS #:TX2275000
OSHA PEL:1000 PPM
ACGIH TLV:ASPHYXIANT
Ingred Name:BUTANE
CAS:106-97-8
RTECS #:EJ4200000
OSHA PEL:800 PPM
ACGIH TLV:800 PPM
Ingred Name:METHANE, DICHLORO-; (METHYLENE CHLORIDE). EVAP RATE: 1.47
(BUAC=1)
CAS:75-09-2
RTECS #:PA8050000
Fraction by Wt: 15-30%
OSHA PEL:500 PPM/1000, C
ACGIH TLV:50 PPM
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ingred Name:MINERAL OIL, SLAB OIL; (WHITE MINERAL OIL)
CAS:8042-47-5
RTECS #:PY8047000
Other REC Limits:5MG/M3 OIL MIST(MFR)
Ingred Name:PETROLEUM HYDROCARBON; (NON-HAZARDOUS PETROLEUM
HYDRACARBON)
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:INHAL: DIZZ. SKIN: IRRIT & DEFAT OF
SKIN ON PRLNGD/RPTD CONT. EYE: IRRIT & SLIGHT CORNEAL INJ. PRLNGD
OVEREXP HAS CAUSED TOX EFTS IN LIVER & KIDNEYS OF EXPERIMENTAL
ANIMALS & HAS CAUSED CANCER IN CERT AIN LAB ANIMAL TESTS.FINDING OF
SUCH EFTS IN EXPERIMENTAL ANIMALS MAY INDICATE POTENTIAL HAZ TO
HUMANS.(EFTS OF OVEREXP)
Explanation of Carcinogenicity:METHYLENE CHLORIDE: GROUP 2 (NTP), 2B
(IARC).
Effects of Overexposure:HLTH HAZ: NOTE TO PHYS: CONT CHLORINATED SOLV.
INCR CARDIAC SENSIT & POSS ARRHYTHMIA MAY RSLT FROM OVEREXP. DO NOT
ADMIN EPINEPHRINE/OTHER STIMULANT FOLLOWING OVEREXP. CHLOROCARBON
MATLS HAVE PRDCED S ENSIT OF MYOCARDIUM TO EPINEPHRINE IN LAB
ANIMALS & COULD HAVE SIMILAR EFT IN HUMANS. ADRENOMIMETICS
(E.G.,(SUPP DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:SKIN: FLUSH AREA WELL WITH WATER. REMOVE AND WASH ANY
CLOTHING SOAKED WITH PRODUCT. EYE: FLUSH EYES WELL WITH RUNNING
WATER FOR AT LEAST 15 MINUTES. INGESTION: CALL PHYSICIAN OR POISON
CONTROL CENTER IMMEDIATELY. PROPER TREATMENT IS DEPENDENT ON
CONDITION OF PATIENT AND AMOUNT INGESTED. INHALATION: REMOVE FROM
EXPOSURE. SUPPORT BREATHING (GIVE ARTIFICIAL RESPIRATION/OXYGEN).
CALL MD .
===================== Fire Fighting Measures =====================
Flash Point:-156F,-104C
Lower Limits:1.9%
Upper Limits:9.5%
Extinguishing Media:FOAM, DRY CHEMICAL, CARBON DIOXIDE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESS DEMAND SCBA AND
FULL PROTECTIVE EQUIPMENT . AVOID POSS ACCUMULATIONS OF VAPS AT
FLOOR LEVEL, AS VAPOR IS HEAVIER THAN AIR.
Unusual Fire/Explosion Hazard:AVOID POSSIBLE BURSTING OF AEROSOL CAN.
DO NOT STORE WHERE TEMP MAY EXCEED 120F. DO NOT
PUNCTURE/INCINERATE. THERM DECOMP PRODS MAY INCL HCL & PHOSGENE .
================== Accidental Release Measures ==================
Spill Release Procedures:VENTILATE AREA WELL. AVOID ANY SOURCES OF
IGNITION FOR FLAMMABLE LIQUID OR VAPOR. SOAK UP ON SUITABLE
ABSORBENT MATERIAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:DO NOT STORE WHERE TEMPERATURES MAY
EXCEED 120F. DO NOT STORE NEAR HEAT, FIRE FLAME OR SPARKS.
Other Precautions:AVOID EXCESSIVE BRTHG OF VAP.DO NOT SPRAY IN
DIRECTION OF BODY.USE ONLY I/A/W/DIRECTIONS.NO SMOKING IN AREA OF
USE.DO NOT USE IN GEN VICINITY OF ARC WELDING,OPEN FLAMES/HOT
SURFS. HEAT &/OR UV RADIA M AY CAUSE FORM OF HCL &/OR PHOSGENE
============= Exposure Controls/Personal Protection =============
Respiratory Protection:IF TLV IS EXCEEDED WEAR NIOSH/MSHA APPROVED
SELF-CONTAINED BREATHING DEVICES OR RESPIRATOR.
Ventilation:MUST BE ADEQUATE TO MAINTAIN VAPORS AT LESS THAN 100 PPM,
PARTICULARLY AT FLOOR LEVEL AS VAPORS ARE HEAVIER THAN AIR.
Protective Gloves:SOLVENT RESISTANT GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EFTS OF OVEREXP: EPINEPHRINE) MAY BE CONTRAINDICATED EXCEPT FOR
LIFE-SUSTAINING USES IN HUMANS ACUTELY OR CHRONICALLY EXPOSED TO
CHLOROCARBONS .
================== Physical/Chemical Properties ==================
HCC:V3
Boiling Pt:B.P. Text:>-44F,-42C
Vapor Pres:55 PSIG
Spec Gravity:1.0
Evaporation Rate & Reference:SEE ING 3
Solubility in Water:SLIGHT
Appearance and Odor:DARK LIQUID, SLIGHT SOLVENT ODOR, SOLVENT
EVAPORATES, LEAVING LUBRICANT RESIDUE
Percent Volatiles by Volume:42(WT)
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:HEAT, SPARKS, FLAMES.
Hazardous Decomposition Products:CO, HCL, CHLORINE, PHOSGENE GAS (SMALL
AMOUNT), OTHER TOXIC GASES POSS IF THERM DECOMP.
==================== Disposal Considerations ====================
Waste Disposal Methods:CONVENTIONAL SOLVENT WASTE RECEPTACLE. DISPOSE
OF IN ACCORDANCE WITH ALL LOCAL, STATE AND FEDERAL REGULATIONS.
AVOID CONTAMINATION OF GROUNDWATER.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.